Old Electrical Service: Time to Upgrade?

Many houses built in the last century were constructed with minimal electrical service. When looking back to those times, there simply weren’t that many electrical devices in a home. Air conditioners weren’t readily available until after World War II, and in 1955 only 10 percent of U.S. households had electric clothes dryers. Hair dryers, toaster ovens, electric ranges, microwaves, electric water heaters and other such things were added over the years, greatly increasing electrical demands.

A round-base meter usually means electrical service of only 50 to 60 amps.

A round-base meter usually means electrical service of only 50 to 60 amps.

With few of today’s modern conveniences, a house could easily get by with only 50-60 Amps of electrical service, and even today this level of service does not pose a problem, as long as electrical devices are kept to a minimum. However, when homeowners with such basic service start adding modern appliances, they quickly run out of electrical capacity, which can result in local brownouts, blown breakers or fuses, or overheating of wires and a possible fire hazard.

A meter with a small square base is also common with feeds of 50 to 60 amps. Also, noice the frayed service entrance cable on the left.

A meter with a small square base is also common with feeds of 50 to 60 amps. Also, noice the frayed service entrance cable on the left.

Computers don’t take much, but they don’t like brownouts or flickers in power. For any type of computer or computerized appliance, it’s a good idea to use surge suppressors and uninterruptible power supplies to prevent damage. This includes computerized sewing machines, exercise equipment, TVs, digital video recorders, and cable boxes.

A large rectangular base usually means a home is supplied with 150A to 200A.

A large rectangular base usually means a home is supplied with 150A to 200A.

Another consideration when with older homes is that many of the wires coming from the poles to the house, and then down the house to the meter, are 40-50 years old and are now frayed. Often the wire wrapped around the central conductors is now showing through. Contrary to common belief, that is not a ground, but a current-carrying conductor, often carrying substantial current. Although wrapping with tape is acceptable by some, most electricians agree that frayed Service Entrance (SE) cables should be replaced for safety. At a minimum, that wire needs to be replaced so that it is safe and it is a good opportunity to UPGRADE the entire service to a more modern 150-200A service. Most municipalities won’t install less than 125-150A, and most times 200A service is the same price as the lower, so 200A is installed. Even Townhouses and condominiums now are provided with 125-150A service per unit.

This extra-large rectangular meter enclosure is an indication that the service to the house is 400A.

This extra-large rectangular meter enclosure is an indication that the service to the house is 400A.

Some all-electric homes, or homes with lots and lots of circuits, may even need a larger service (400A) because of the requirement for no more than 42 circuits per panel, and 150-200A per panel.  With the new rules, the number of circuits per panel is being relaxed, but homes with multiple air conditioners, water heaters, second kitchens, clothes dryers, guest quarters and other large users of electricity may still need the larger electrical service.

Modern Life Consumes Electricity

Here are typical amperage requirements for some common household appliances.

Electric Range:  40A

Wall Oven: 40A

Modern Electric Clothes Dyer: 30A (min.)

Air Conditioner, outside unit: 25A (min.)

Air Conditioner, inside unit: 15A

Microwave: 12A

Toaster: 12A

Hair Dryer: 12A

Dishwasher: 15A

To calculate how many amps an appliance needs, divide the wattage by 120 (normal household voltage). For example, a microwave oven that uses 1800 watts needs a 15 amp circuit. (Amps = Watts/Volts)

Safety Note

The service entry cable should always be protected from the elements, and from the possibility of abrasion or fraying. Soil settling around the foundation of a house can pull the cable conduit away from the meter box, with potentially disastrous consequences.

This cable could rub against the meter housing and lead to a house fire.

This cable could rub against the meter housing and lead to a house fire.

Share and Enjoy:
  • Digg
  • del.icio.us
  • Facebook
  • Mixx
  • Google
  • LinkedIn
  • MySpace
  • Pownce
  • StumbleUpon
  • Technorati
  • TwitThis
This entry was posted in Bad Things, Information, Maintenance and tagged , , , , . Bookmark the permalink.

2 Responses to Old Electrical Service: Time to Upgrade?

  1. Incredible, that’s precisely what I was looking for! You just saved me alot of looking around

  2. Ashley says:

    hey, nice blog…really like it and added to bookmarks. keep up with good work

Leave a Reply

Your email address will not be published. Required fields are marked *

*

You may use these HTML tags and attributes: <a href="" title=""> <abbr title=""> <acronym title=""> <b> <blockquote cite=""> <cite> <code> <del datetime=""> <em> <i> <q cite=""> <strike> <strong>

Inspections by Bob, LLC
Telephone:     301-208-8289
18505 Crossview Road, Boyds, MD 20841

Page copy protected against web site content infringement by Copyscape

inspectionsbybob.com and the editorial content, graphics, and products of the inspectionsbybob.com website, unless otherwise noted, are the products of Inspections By Bob. The information presented on inspectionsbybob.com is copyrighted as collective work. Any unauthorized reproduction, by any means, mechanical or electronic, without the express written permission of Inspections By Bob. is strictly prohibited.